Would there be an affect on the color amp response from the other color circuits such as the oscillator or demodulator? To get the TV up and running I avoided replacing most all ceramic capacitors. Below are the ones that measured way off.
- C92 & C93 - all 4 .001uf measured 18-21% low
- C103 - .001uf measured 19% low, is this just for bypass? or would this affect the 3.58 oscillator
- C104 - 100pf measured 17% high but this was measuring in circuit, I suspect this will measure right on if I pull a lead
- C67 - 100pf measured 28% high but this was measuring in circuit, same thing I suspect this will measure right on if I pull a lead
- C69 - .001uf measured 18% low
- Note capacitors under 100pf may have measured high or low but without pulling them complete out they are hard to measure and I am assuming they are ok.