#1
|
||||
|
||||
|
The tube shouldn't make any difference, unless it is the cause of leakage... try it both ways. You could also check the tube itself for any leakage between pins, but since you have tried several different tubes without changing the symptoms, it is unlikely that you will find any leakage unless they all have the same fault.
jr |
|
#2
|
|||
|
|||
|
Timmy,
Did you ever try spraying any cleaner into the vertical hold and size control to see if it would stabilize the vertical roll? Did you try wiggling V9, V11, or V12 while the set is on to see if it helped? I come across worn and dirty contacts all the time in old equipment. The cause of all sorts of issues. Just because parts are swapped or tested doesn't always eliminate the root cause. Do you understand how the vertical feedback loop works with this set? If you have a scope, check to see if you are getting the proper trigger signal to your vertical oscillator grid from the sync separator/ integrator network. Ed |
|
#3
|
||||
|
||||
|
Quote:
Last edited by timmy; 03-23-2017 at 07:58 PM. |
|
#4
|
|||
|
|||
|
Tim,
Since you don't have a scope you could try to isolate the trouble better. Disconnect/ unsolder C61 250mmf from pin 4 of V9. Leave C61 disconnected and then turn on the set. The picture should roll but, see if you can adjust the vertical size, if so set it. Next see if the vertical hold control has any effect on the vertical roll. If you can get the vertical roll to almost stop with the vertical hold in mid-position thats good. If the vertical hold has no effect or won't slow down enough then the trouble could well be a bad cap or resistor. The bad cap or resistor would determine the time constant the free running vertical oscillator frequency. If the vertical roll can be slowed down and controlled, then I would next start checking the output of the sync separator. Try connecting a voltmeter set on AC volts, high range to start, to the end of the disconnected C61. You should be getting an AC voltage reading of some sort. You may have to adjust your voltmeters range downward to get a better reading. If there is no AC voltage present then the trouble is syn related. The integrated sync pulse voltage is what your trying to measure. Try these steps and let us know the results. |
|
#5
|
||||
|
||||
|
Quote:
Last edited by timmy; 03-24-2017 at 06:33 AM. |
| Audiokarma |
|
#6
|
|||
|
|||
|
If you can't get the vertical to stop rolling with the hold control, (with the sync pulse disconnected) it seems as thought he vertical oscillator is off frequency. You should be able to get the picture to get close however, it needs sync to lock in.
You might check the capacitors in the oscillator circuit to be sure the correct value is there. Also, resistors for one that may have gone high in value or maybe one that was replaced with a value that is 10 off (Like 270KΩ instead of 27KΩ or .01 ᶙFD instead of .001 ᶙFd). Just a thought. I realize how maddening it is! |
![]() |