#10
|
||||
|
||||
|
Quote:
Yes, I was removing some of the white gunky stuff from around the edges with spudger tool Friday, I got a lot out, and I stuck 4 of them across from each other between the safety glass and tube in order to open the gap a bit more, I could see the gap flexing as I did, but as it was being out back into the water, one spudger bumped the edge of the tube and the safety glass cracked. Sucks, but no REAL big deal, was able to get the rest off w/o too much trouble, and as I have nothing to replace it with, and am very unlikely to ever get one, I put it in as-is. Looks pretty OK. Right now, I'm more zeroed in on the HV problem, why I can't get it to 24kv like it should be, if I try, focus goes to hell, which MAY be because the CRT socket is crappy, and all carbon arced around the pin for focus, AND/OR as mentioned the HOT/HV rect tubes are all old, new socket and tubes ordered. Am also seeing symptoms of bad caps in the Y amps, the level of red is jumping all over the place, just like blue was before I replaced them in my CTC-16
__________________
=^-^= Yasashii yoru ni hitori utau uta. Asu wa kimi to utaou. Yume no tsubasa ni notte. いとおしい人のために |