Videokarma.org

Go Back   Videokarma.org TV - Video - Vintage Television & Radio Forums > Early Color Television

Notices

We appreciate your help

in keeping this site going.
Reply
 
Thread Tools Display Modes
  #1  
Old 02-03-2010, 12:04 PM
ctc17 ctc17 is offline
VideoKarma Member
 
Join Date: Jul 2009
Posts: 1,615
They can take one apart and rewind it? That would be a good thing as transformers for these old sets are becoming impossible to find.

I dissembled a zenith vert out transformer with a primary to secondary short and the insulation between the two winding was very poor. It was like one turn of clear tape and it had a little hole burned through it. Looked to me like they were relying to much on the wires varnish, theres a fairly high potential between those windings and there should have been more tape.
Reply With Quote
  #2  
Old 02-03-2010, 01:22 PM
Zenith26kc20's Avatar
Zenith26kc20 Zenith26kc20 is offline
VideoKarma Member
 
Join Date: Apr 2009
Location: New Orleans
Posts: 854
They have reverse engineered a number of transformers for me. One of the strangest was the start transformer for one of my Infinity SWAMPS. They have been in business for a long time and apparently have made almost every transformer imaginable over the years.
It seems to me that Zenith put the plate connection on the inside part of the winding. This has 1200 volts signal (vertical) and 390 volts DC. When mine failed, it appears that the puncture in insultion would cause the arcing that I noticed, but no sign of distress with the 6HE5 pulled. It also makes sense with JK unhooked. I noticed a set on EBAY that the owner says gives a picture with the convergence panel unplugged. Unplugging the panel disconnects JK so that set may need a transformer too.
It the winding had the plate end outside, the only thing between windings would be 390 volts.
The engineer at TMI said the insulation may only be 3 mils thick (the nearly transparent tape). No wonder it may get into trouble....
Reply With Quote
  #3  
Old 02-04-2010, 05:19 PM
wa2ise's Avatar
wa2ise wa2ise is offline
VideoKarma Member
 
Join Date: Dec 2002
Location: USA
Posts: 3,147
Quote:
Originally Posted by Zenith26kc20 View Post
It seems to me that Zenith put the plate connection on the inside part of the winding. This has 1200 volts signal (vertical) and 390 volts DC. When mine failed, it appears that the puncture in insulation would cause the arcing that I noticed, but no sign of distress with the 6HE5 pulled. It also makes sense with JK unhooked....
The engineer at TMI said the insulation may only be 3 mils thick (the nearly transparent tape). No wonder it may get into trouble....
Maybe one should mount the transformer with its frame and core insulated from the chassis ground. Thus making life on the insulation a little easier. Though the transformer frame would become a shock hazard, but once the TV is back together that shouldn't be a big issue.
__________________
Reply With Quote
  #4  
Old 02-08-2010, 11:18 AM
compucat's Avatar
compucat compucat is offline
1949 Motorola 9VT1
 
Join Date: Apr 2005
Location: Suffolk, VA
Posts: 970
This is really interesting. I have a 25MC33 Zenith Roundie and I have had this happen twice with the vertical output transformer. I would definitely like to find a permanent fix. If better replacements could be made, I would be interested in buying one. This does seem to be the only real weakness in the Zenith roundie design. Lets us know what happens with the transformer.
__________________
Just look at those channels whiz on by. - Fred Sanford
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 12:59 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.