Videokarma.org

Go Back   Videokarma.org TV - Video - Vintage Television & Radio Forums > Early B&W and Projection TV

Notices

We appreciate your help

in keeping this site going.
 
 
Thread Tools Display Modes
Prev Previous Post   Next Post Next
  #39  
Old 07-01-2016, 09:05 AM
timmy's Avatar
timmy timmy is offline
VideoKarma Member
 
Join Date: Jan 2011
Location: Delaware ny
Posts: 3,708
Quote:
Originally Posted by Electronic M View Post
I'd imagine that they kept the vertical stage fairly standard across models...Trace your vertical stage and compare it to the schematics of all listed models that use similar vertical stage tubes to yours...If the vertical stage matches (or is very close), and uses similar B+ voltages, then all the tube base voltages on the vert section of the schematic should be used as references and compared to those in the set.
What's kind of odd is I compared the teletone tv149 voltages and the tv208 and they don't come close and the tv208tr voltages I don't have as I only have the schematic not the resistance and voltage charts. This verticle problem is minor I'm sure because everything is working fine except turning the size pot it stops filling in then gets a white line across the top almost to say it went over some limit. The pot I checked and it's good and also the resistor from the pot to the tube. I have 410vdc at the size pot but don't know if it's the right voltage.
Reply With Quote
 



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 01:17 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.