#4
|
||||
|
||||
|
May not be CRT. You can tap the neck & see if it comes & goes
but you also shake the CRT board. Most sets the filament comes off the FBT & one side goes to ground. You have to lift it above ground & if its grounded in the FBT out of luck. Also when you get a H-K short USUALLY the K goes to 0 V & lights up bright the bad color then set goes into shut down. Another test is lift the blue K & one of the others. run jumpers to swap the K's & see if the blue still acts up or it goes over to the other color. Do it with a B&W pix to save confusion !! Sears had a crap load of 19" Sanyos with Sylvania jugs shorting. Cure was get the filament above ground & add a 1.5 meg & .001 cap but I dont remember where ! IIRC the resistor went from the bad K to filament but dont remember where the cap went ![]() BTW someone used to make an isolation booster that worked on the sweep freq. You would wire it for no boost. Maybe Brian remembers ? 73 Zeno ![]() LFOD ! |
|
|