#9
|
||||
|
||||
|
Your MGA uses an RCA bonded yoke CRT. Yoke is glued on
& the neck magnets are a piece of grey tape. Do NOT remove the tape ! Three possable problems with purity. 1) CRT is heavily magnetized & the DGS circuit cant handle it. It will improve with time ( cold restarts). 2) There is a cold joint in the DGS or a bad DGS thermistor. & the DGS circuit is not working right. Thermistor usually abt a 1/2" black square part made by TDK. Either 2 or 3 legs. 3) The set fell & the shadow mask broke loose. Nothing you can do about that. Usually if you hit the set hard the purity problem will shift. Beyond that the RCA CRT was a common jug. Many Japan & US set used them & you can swap one out in minutes. Buzz most likely from the yoke vert winding. NAP sets were a big problem with it. We sprayed it with something it a rattle can but I dont remember what ! Someone here will. To track down buzzes & screams use a paper towel tube as a stethiscope or a plastic rod to poke at things. good luck 73 Zeno ![]() LFOD ! |
|
|