#16
|
||||
|
||||
|
Quote:
Quote:
Radiation decontamination actually....I take it you haven't seen the james Bond Film 'Dr. No' before... Before I turned down the B+ to spec it filled the screen and was running 235mA H out cathode current and the fly was gettign hot after 40 min running. After getting B+ to spce it was running 180mA, but didn't fill the screen. I then subbed a better tube and currently have the compromise fo full screen and 220mA (cathode current had to be adjusted off dip for a full screen)... H centering is at one end. which don't help...I may in the future try to get it better. For now it is good enough that I can try to work on other stuff and get unburied in projects.
__________________
Tom C. Zenith: The quality stays in EVEN after the name falls off! What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4 |
|
#17
|
|||
|
|||
|
Did anyone manage to locate a scan of the service manual for this monitor? I'd imagine that the one for the CYA would also have quite a bit of overlapping information.
|
|
#18
|
||||
|
||||
|
The one Kf4RCA posted is correct and all I have presently....The set was working fine when I last used it the last time this thread was active so I'm not worried.